iLaser I
Soga
A diode laser from Soga for soft-tissue use in the dental clinic: cutting, coagulation and periodontal treatment, with a thin optical fiber that reaches areas mechanical instruments struggle with. It suits anyone who folds soft-tissue treatment into routine work and wants precise power control per indication. Supply, installation, staff training and maintenance by JK Dent.
- Supply, installation and staff training by JK Dent
- Full warranty
- Service and maintenance — response within 24 hours
Technical specifications
- Type
- desktop diode laser, Class IV, InGaAsP
- Wavelength
- 980 nm
- Power
- 0.5–8 W
- Emission modes
- continuous and pulsed
- Aiming beam
- 650 nm, under 2 mW
- Optical fibers
- 200 and 400 μm
- Display
- OLED
- Dimensions
- 190 × 155 × 260 mm
- Supply
- built-in lithium-ion battery
Data as published by the manufacturer. Details vary by configuration — talk to us.
More in this category
New
IMPNAVIMPNAV is an AI-assisted dynamic navigation system for dental implant surgery that links digital preoperative planning with real-time surgical navigation. Planning is built on the patient’s CT data; during surgery an optical tracking system follows the instrument tip and shows the clinician, in 3D, the drilling position, direction and depth against the planned implant position.
Aurora-SA combined laser system: Er:YAG at 2940 nm together with a diode laser at 980, 650 and 450 nm. That combination is the reason to buy a unit like this — Er:YAG is absorbed by water and works on hard tissue and bone without heat building up, while the diode handles soft tissue. One unit therefore covers cavity preparation, bone surgery and soft-tissue cutting. Two laser modes, and the unit rolls between rooms on castors. Class IV — protective eyewear and a room safety protocol are required. Supplied by JK Dent with training and ongoing service.
iLaser I PlusA desktop diode laser with three wavelengths — 450, 650 and 980 nm — in one instrument. The three are not alternatives but complements: each is absorbed by different tissue, so a single unit covers a wider range of indications than a single-wavelength device. Class IV — protective eyewear is required for staff and patient, along with a room safety protocol. Through JK Dent — with warranty and in-clinic service.
iLaser IIA pen-body diode laser weighing 106 g with an internal battery — no benchtop unit and no mains cable. Its 980 nm wavelength is well absorbed by water and hemoglobin, so it cuts soft tissue and coagulates in the same pass; the cut comes out clean without bleeding that obscures the field. Continuous power reaches 3 W with a 5 W pulse peak, adjustable from 0.5 W upward, with 200 and 400 μm fibers and a red aiming beam. Class IV — protective eyewear is required for staff and patient. Supplied by JK Dent with training and ongoing service.
IMPNAVIMPNAV is an AI-assisted dynamic navigation system for dental implant surgery that links digital preoperative planning with real-time surgical navigation. Planning is built on the patient’s CT data; during surgery an optical tracking system follows the instrument tip and shows the clinician, in 3D, the drilling position, direction and depth against the planned implant position.
Aurora-SA combined laser system: Er:YAG at 2940 nm together with a diode laser at 980, 650 and 450 nm. That combination is the reason to buy a unit like this — Er:YAG is absorbed by water and works on hard tissue and bone without heat building up, while the diode handles soft tissue. One unit therefore covers cavity preparation, bone surgery and soft-tissue cutting. Two laser modes, and the unit rolls between rooms on castors. Class IV — protective eyewear and a room safety protocol are required. Supplied by JK Dent with training and ongoing service.
iLaser I PlusA desktop diode laser with three wavelengths — 450, 650 and 980 nm — in one instrument. The three are not alternatives but complements: each is absorbed by different tissue, so a single unit covers a wider range of indications than a single-wavelength device. Class IV — protective eyewear is required for staff and patient, along with a room safety protocol. Through JK Dent — with warranty and in-clinic service.
iLaser IIA pen-body diode laser weighing 106 g with an internal battery — no benchtop unit and no mains cable. Its 980 nm wavelength is well absorbed by water and hemoglobin, so it cuts soft tissue and coagulates in the same pass; the cut comes out clean without bleeding that obscures the field. Continuous power reaches 3 W with a 5 W pulse peak, adjustable from 0.5 W upward, with 200 and 400 μm fibers and a red aiming beam. Class IV — protective eyewear is required for staff and patient. Supplied by JK Dent with training and ongoing service.
Contact us
A site visit, measurements and an initial plan with a price range — no obligation.
Leave a detailed message
Even outside business hours — we will get back to you.